<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T20:13:23Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/4513" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/4513</identifier><datestamp>2025-05-01T02:19:07Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Aye Aye Khaing</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Zhu, Kuanyi</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="fd1602b1-1a0d-46db-93fa-8a833a7505d9" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2008-09-17T09:52:57Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2008-09-17T09:52:57Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2005</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10356/4513</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">This report deals with modeling and computer simulation of the cardiovascular system. The modeling focuses on the left heart and the complete cardiovascular system modeled close to the actual heart. Specific attention is given to the modeling of blood flow in the cardiovascular system. The cardiovascular system has been modeled using compartmental modeling for the arteries and veins. In this study, the analogy between parameters and variables that characterizes the left heart and corresponds to electrical circuit quantities is explored for the modeling as well as simulation. The simple model of the left heart is first simulated using half-square waveform as the inputs to run the model. The complete heart is also modeled using the lumped capacitance circuit and is followed by an improvement using a single-loop circuit. Finally, a complete model of a nonlinear pulsatile-flow patient model is developed. The use of the pulsatile model yields the desired accuracy, and the execution time is reduced. To complete the simulator, a mass pharmacologic model of SNP (pharmacokinetic and pharmacodynamic models) is also determined, and combined with the cardiovascular model. The common method for most pharmacologic agents to treat hypertension is relaxing the considered arterioles to decrease the resistance of peripheral blood flow.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (Computer Control and Automation)</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Medical electronics</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Cardiovascular system modeling and simulation</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="ca88ddb1-267f-4b58-9fcc-de5d0c3d0091">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>Cardiovascular system modeling and simulation&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2005&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Aye Aye Khaing&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Medical electronics&lt;/Keyword>
   	&lt;Abstract>This report deals with modeling and computer simulation of the cardiovascular system. The modeling focuses on the left heart and the complete cardiovascular system modeled close to the actual heart. Specific attention is given to the modeling of blood flow in the cardiovascular system. The cardiovascular system has been modeled using compartmental modeling for the arteries and veins. In this study, the analogy between parameters and variables that characterizes the left heart and corresponds to electrical circuit quantities is explored for the modeling as well as simulation. The simple model of the left heart is first simulated using half-square waveform as the inputs to run the model. The complete heart is also modeled using the lumped capacitance circuit and is followed by an improvement using a single-loop circuit. Finally, a complete model of a nonlinear pulsatile-flow patient model is developed. The use of the pulsatile model yields the desired accuracy, and the execution time is reduced. To complete the simulator, a mass pharmacologic model of SNP (pharmacokinetic and pharmacodynamic models) is also determined, and combined with the cardiovascular model. The common method for most pharmacologic agents to treat hypertension is relaxing the considered arterioles to decrease the resistance of peripheral blood flow.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>