<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T01:32:01Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/46480" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/46480</identifier><datestamp>2026-11-27T20:18:07Z</datestamp><setSpec>com_10356_1420</setSpec><setSpec>com_10356_21</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2324</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en">Hui, Yan Lan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en">Richard David Webster</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en" authority="07ed7c33-4ecb-4d69-9eda-16cd1f130014" confidence="600">School of Physical and Mathematical Sciences</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned" lang="en">2011-12-12T06:40:37Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available" lang="en">2011-12-12T06:40:37Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en">2011</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en">2011</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation" lang="en">Hui, Y. L. (2011). Voltammetric studies on vitamin K1 in organic solvents. Doctoral thesis, Nanyang Technological University, Singapore.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/46480</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi" lang="en">10.32657/10356/46480</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Vitamin K1 (VK1) was shown by voltammetry to undergo two chemically reversible one-electron reduction processes in organic solvents containing Bu4NPF6 as the supporting electrolyte. The potential separation between the first and second electron transfer steps diminished sequentially with the addition of water. The voltammetric behavior was interpreted based on the degree of hydrogen-bonding between the reduced forms of VK1 with water in the solvents. It was found that the potential separation between the first and second processes was especially sensitive to water in the low molar levels (0.001 – 0.1 M), therefore; by measuring the peak separation as a function of controlled water concentrations (accurately determined by Karl Fischer coulometric titrations) it was possible to prepare calibration curves of peak separation versus water concentration. The water content of the solvents was accurately measured using KF coulometric titrations. Calibration data were obtained which are independent of the nature of the reference electrode, and allow the water content of the solvents to be calculated by performing a single voltammetric scan in the presence of VK1 and 0.2 M supporting electrolyte (Bu4NPF6).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en">CHEMISTRY and BIOLOGICAL CHEMISTRY</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en">201 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">DRNTU::Science::Chemistry::Analytical chemistry</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Voltammetric studies on vitamin K1 in organic solvents</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-27T20:18:06Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="wos">2025-08-14T00:24:09Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="4b010bb6-7f63-4dea-b52f-e53eae80c00f">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Voltammetric studies on vitamin K1 in organic solvents&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2011&lt;/PublicationDate>
   	&lt;DOI>10.32657/10356/46480&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Hui, Yan Lan&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Science::Chemistry::Analytical chemistry&lt;/Keyword>
   	&lt;Abstract>Vitamin K1 (VK1) was shown by voltammetry to undergo two chemically reversible one-electron reduction processes in organic solvents containing Bu4NPF6 as the supporting electrolyte. The potential separation between the first and second electron transfer steps diminished sequentially with the addition of water. The voltammetric behavior was interpreted based on the degree of hydrogen-bonding between the reduced forms of VK1 with water in the solvents. It was found that the potential separation between the first and second processes was especially sensitive to water in the low molar levels (0.001 – 0.1 M), therefore; by measuring the peak separation as a function of controlled water concentrations (accurately determined by Karl Fischer coulometric titrations) it was possible to prepare calibration curves of peak separation versus water concentration. The water content of the solvents was accurately measured using KF coulometric titrations. Calibration data were obtained which are independent of the nature of the reference electrode, and allow the water content of the solvents to be calculated by performing a single voltammetric scan in the presence of VK1 and 0.2 M supporting electrolyte (Bu4NPF6).&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>