<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T13:53:21Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/46989" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/46989</identifier><datestamp>2025-05-14T15:49:17Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Dhanasekaran Shrishailesh</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Sunita Chauhan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2011-12-27T05:52:30Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2011-12-27T05:52:30Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2009</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2009</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/46989</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">80 p.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Medical robotics and computer assisted surgery are used in a growing number of operating rooms around the world, largely as a result of the popularity of minimally invasive and non-invasive surgical techniques. Minimally invasive and non-invasive surgical techniques are gaining importance in bio-medical research areas. Radiation therapy is the commonly used technique for non- invasive treatment. Due to tissue ionisation, radiation therapy has many side effects such as oedema, damage to epithelium and fatigue. High Intensity Focused Ultrasound (HIFU) is devoid of ionizing effects making it more suitable for organs such as brain which have low radiation tolerance. In oncology HIFU can be used for highly focussed non-invasive tissue ablation ensuring&#xd;
minimal damage to surrounding tissue. Focused Ultrasound Surgery- FUSBOT developed by Biomechatronics group, Robotic Research Centre (RRC), NTU for a series of robots for precise positioning and feedback in FUS.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (Computer Control and Automation)</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Robotics</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Inverse kinematics of a single probe effector for a non-invasive brain surgery robot Fusbot-NS</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="09ffa1fe-5872-4408-98db-d97e4ada24a5">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>Inverse kinematics of a single probe effector for a non-invasive brain surgery robot Fusbot-NS&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2009&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Dhanasekaran Shrishailesh&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Robotics&lt;/Keyword>
   	&lt;Abstract>Medical robotics and computer assisted surgery are used in a growing number of operating rooms around the world, largely as a result of the popularity of minimally invasive and non-invasive surgical techniques. Minimally invasive and non-invasive surgical techniques are gaining importance in bio-medical research areas. Radiation therapy is the commonly used technique for non- invasive treatment. Due to tissue ionisation, radiation therapy has many side effects such as oedema, damage to epithelium and fatigue. High Intensity Focused Ultrasound (HIFU) is devoid of ionizing effects making it more suitable for organs such as brain which have low radiation tolerance. In oncology HIFU can be used for highly focussed non-invasive tissue ablation ensuring&#xd;
minimal damage to surrounding tissue. Focused Ultrasound Surgery- FUSBOT developed by Biomechatronics group, Robotic Research Centre (RRC), NTU for a series of robots for precise positioning and feedback in FUS.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>