<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T09:48:49Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/53209" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/53209</identifier><datestamp>2025-05-14T19:13:42Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Gui, Jingkang.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2013-05-30T08:01:12Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-05-30T08:01:12Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2012</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/53209</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">A pressurized water reactor (PWR) consists of two coolant systems to convert the heat originates from fission process into electrical power. The primary system pumps the not boiling light water (coolant and neutron moderator), in the state of high temperature and high pressure, to the steam generator where it transfers thermal energy to the secondary system via heat transfer processes. The steam generated flows to turbines to generate electricity, and passes through the main condenser and become cool water. The water is then pumped back to the steam generator and forms a cycle. In real applications, there are around one hundred support systems to assure the two systems function properly. In addition, special systems are designed to combat with emergencies.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">102 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Lift-off issues for high performance annular fuels in pressurized water reactors</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="4bc39aee-9daf-43e3-a776-8851c7bdcf2f">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Lift-off issues for high performance annular fuels in pressurized water reactors&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2012&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Gui, Jingkang.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering&lt;/Keyword>
   	&lt;Abstract>A pressurized water reactor (PWR) consists of two coolant systems to convert the heat originates from fission process into electrical power. The primary system pumps the not boiling light water (coolant and neutron moderator), in the state of high temperature and high pressure, to the steam generator where it transfers thermal energy to the secondary system via heat transfer processes. The steam generated flows to turbines to generate electricity, and passes through the main condenser and become cool water. The water is then pumped back to the steam generator and forms a cycle. In real applications, there are around one hundred support systems to assure the two systems function properly. In addition, special systems are designed to combat with emergencies.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>