<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T20:50:37Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/5605" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/5605</identifier><datestamp>2025-05-01T02:10:32Z</datestamp><setSpec>com_10356_986</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2218</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Chia, Chee Tat.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Khor, Khiam Aik</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="a3f00e0c-49f5-4bb6-a408-66ee7120b40a" confidence="600">School of Mechanical and Production Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2008-09-17T10:54:46Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2008-09-17T10:54:46Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2000</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2000</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10356/5605</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Plasma sprayed thermal barrier coatings are used extensively in dynamic environment which are exposed to noise and vibration. Economic, building efficient and lightweight reasons have encouraged the increased use of vibration damping materials compared to the alternative of component redesign and retrofit. Therefore, it is important to understand the dynamic mechanical properties of coatings as well, which will be used in the dynamic conditions. An added motivation would be that the damping measurement allowed insight into the rate parameters governing the kinetics of various internal transport processes.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Engineering (MPE)</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">DRNTU::Engineering::Materials::Plasma treatment</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Dynamic mechanical and thermal shock characteristics of NiCoCrAlY/YSZ composite coatings</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="c873abad-7283-4987-9fbb-2d58f85ff326">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>Dynamic mechanical and thermal shock characteristics of NiCoCrAlY/YSZ composite coatings&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2000&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Chia, Chee Tat.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Materials::Plasma treatment&lt;/Keyword>
   	&lt;Abstract>Plasma sprayed thermal barrier coatings are used extensively in dynamic environment which are exposed to noise and vibration. Economic, building efficient and lightweight reasons have encouraged the increased use of vibration damping materials compared to the alternative of component redesign and retrofit. Therefore, it is important to understand the dynamic mechanical properties of coatings as well, which will be used in the dynamic conditions. An added motivation would be that the damping measurement allowed insight into the rate parameters governing the kinetics of various internal transport processes.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>