<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T00:39:27Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/60716" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/60716</identifier><datestamp>2025-05-14T20:44:08Z</datestamp><setSpec>com_10356_2332</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2333</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Lin, Manfred Yongliang</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Tor Shu Beng</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="50c1ae5d-dbc2-4261-8647-8a6bc78fd13d" confidence="600">School of Mechanical and Aerospace Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="research" lang="en_US" authority="10dab9af-0a51-4c56-8d57-957f429a0ac8" confidence="600">Singapore-MIT Alliance Programme</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2014-05-29T07:03:06Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2014-05-29T07:03:06Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2009</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2009</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/60716</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Injection molding is a popular method for manufacturing microfluidic devices as it is an established technique for large scale production volumes. Devices with different geometry, features and materials will have different optimal process parameters. This study aims to optimize the replication quality of a microchannel cross section area in a micromixer device fabricated using Polymethyl methacrylate (PMMA) by applying Design of Experiment (DOE) method. Eight factors, melt and mold temperature, injection speed and pressure, holding time and pressure, cooling time, and the application of material pre-drying, were screened for significance. Melt temperature is the most significant factor, followed by mold temperature, injection speed, and hold pressure. The optimized settings were determined to be at high melt temperature, mold temperature and hold pressure, with low injection speed.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">​Master of Science (IMST)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">66 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Manufacturing</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Experimental investigation to optimize injection molding process of microfluidic device</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="6921eee8-4c95-4510-b212-b38ec3b8ea03">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Experimental investigation to optimize injection molding process of microfluidic device&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2009&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Lin, Manfred Yongliang&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Manufacturing&lt;/Keyword>
   	&lt;Abstract>Injection molding is a popular method for manufacturing microfluidic devices as it is an established technique for large scale production volumes. Devices with different geometry, features and materials will have different optimal process parameters. This study aims to optimize the replication quality of a microchannel cross section area in a micromixer device fabricated using Polymethyl methacrylate (PMMA) by applying Design of Experiment (DOE) method. Eight factors, melt and mold temperature, injection speed and pressure, holding time and pressure, cooling time, and the application of material pre-drying, were screened for significance. Melt temperature is the most significant factor, followed by mold temperature, injection speed, and hold pressure. The optimized settings were determined to be at high melt temperature, mold temperature and hold pressure, with low injection speed.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>