<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T20:32:29Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/64816" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/64816</identifier><datestamp>2025-05-01T00:42:58Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Govindasamy Praveen Kumar</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Cai Wenjian</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="fd1602b1-1a0d-46db-93fa-8a833a7505d9" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2015-06-04T07:20:26Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2015-06-04T07:20:26Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2014</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2014</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10356/64816</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Active Chilled Beam (ACB) type Heating, Ventilation and Air Conditioning&#xd;
(HVAC) systems has grown a great deal of interest and attention in the past decade.&#xd;
ACBs are favoured by consumers when they plan to implement a HVAC system. Its&#xd;
tremendous scope is due to the inherent benefits that it offers such as cost savings,&#xd;
less maintenance, Energy Savings and reduced Building Space Requirements. This&#xd;
thesis discusses on implementing a suitable control for controlling the water flow&#xd;
rate in ACBs. Automatic System Identification is designed and implemented to&#xd;
reduce engineer's time in designing a controller apt for the system. Modelling of the&#xd;
system, design of controller, tuning and implementation is done in a LabVIEW&#xd;
program. A comparison between designed PID and Fuzzy controller is discussed in&#xd;
detail in this report.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (Computer Control and Automation)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">59 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Control of water flow rate in ACB-HVAC systems</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="b3518f46-b4a5-4cd8-b851-7688abd851a6">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Control of water flow rate in ACB-HVAC systems&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2014&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Govindasamy Praveen Kumar&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation&lt;/Keyword>
   	&lt;Abstract>Active Chilled Beam (ACB) type Heating, Ventilation and Air Conditioning&#xd;
(HVAC) systems has grown a great deal of interest and attention in the past decade.&#xd;
ACBs are favoured by consumers when they plan to implement a HVAC system. Its&#xd;
tremendous scope is due to the inherent benefits that it offers such as cost savings,&#xd;
less maintenance, Energy Savings and reduced Building Space Requirements. This&#xd;
thesis discusses on implementing a suitable control for controlling the water flow&#xd;
rate in ACBs. Automatic System Identification is designed and implemented to&#xd;
reduce engineer&amp;apos;s time in designing a controller apt for the system. Modelling of the&#xd;
system, design of controller, tuning and implementation is done in a LabVIEW&#xd;
program. A comparison between designed PID and Fuzzy controller is discussed in&#xd;
detail in this report.&lt;/Abstract>