<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T15:33:29Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/64949" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/64949</identifier><datestamp>2025-05-14T17:05:49Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Liu, Yu</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">So Ping Lam</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2015-06-09T07:57:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2015-06-09T07:57:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2014</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2014</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/64949</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Under the influence of unbalance high voltage direct current (HVDC) system and&#xd;
&#xd;
geomagnetically induced current (GIC), transformers with neutral grounding point&#xd;
&#xd;
may saturate in half cycle due to the injection of DC current. The vibration of&#xd;
&#xd;
transformer, reactive power demand and harmonic components of power system&#xd;
&#xd;
increase significantly, which are harmful to the safety operation of power system.&#xd;
&#xd;
The nonlinear characteristics of iron core are described by the magnetizing model,&#xd;
&#xd;
the accuracy of magnetizing model is of vital importance in the analysis of DC bias.&#xd;
&#xd;
Jiles-Atherton model is derived from physical process of magnetization. With only&#xd;
&#xd;
five parameters, this model has an accurate description of magnetizing process, and&#xd;
&#xd;
easy to implement. Therefore, Jiles-Atherton model is widely accepted and used in&#xd;
&#xd;
the modeling of magnetization. However, with the development of Jiles-Atherton&#xd;
&#xd;
model, there are several editions of mathematical description, some of them are even&#xd;
&#xd;
contradict. The different expressions can easily lead to confusion and inaccuracy of&#xd;
&#xd;
modeling. This work compared several editions of Jiles-Atherton model, clarified the&#xd;
&#xd;
mathematical expression of the model based on physical properties. A modified&#xd;
&#xd;
energy conservation equation was proposed and modified Jiles-Atherton model was&#xd;
&#xd;
thus established. Numerical simulation of modified Jiles-Atherton model was carried&#xd;
&#xd;
out, the variation of B-H characteristics under different levels of DC bias were&#xd;
&#xd;
analyzed. The transformer behaviour under DC bias was analyzed with UMEC model, the&#xd;
&#xd;
result show that the magnetizing current is seriously distorted due to saturation, the&#xd;
&#xd;
harmonic components increase dramatically. The reactive power demands also&#xd;
&#xd;
increase with DC bias. Influencing factors of DC bias are also discussed. The&#xd;
&#xd;
withstanding ability of transformer to DC bias mainly depends on temperature rise&#xd;
&#xd;
and output voltage harmonics under DC bias, the influence of DC bias on&#xd;
&#xd;
temperature rise and power quality were analyzed based on filed data and limit of&#xd;
&#xd;
DC bias was given according to relevant standard.&#xd;
&#xd;
Finally, possible restraining methods to DC bias were analyzed. DC bias can be&#xd;
&#xd;
restrained by injecting reverse direct current, inserting in series with the neutral point&#xd;
&#xd;
a resistance and install capacitors and bypass device to the neutral point of main&#xd;
&#xd;
transformer.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (Power Engineering)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">69 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Magnetizing model and simulation of transformer behaviour under DC bias</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="2a9a5d47-eed8-4d49-ae78-9d4af8f6e028">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Magnetizing model and simulation of transformer behaviour under DC bias&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2014&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Liu, Yu&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering&lt;/Keyword>
   	&lt;Abstract>Under the influence of unbalance high voltage direct current (HVDC) system and&#xd;
&#xd;
geomagnetically induced current (GIC), transformers with neutral grounding point&#xd;
&#xd;
may saturate in half cycle due to the injection of DC current. The vibration of&#xd;
&#xd;
transformer, reactive power demand and harmonic components of power system&#xd;
&#xd;
increase significantly, which are harmful to the safety operation of power system.&#xd;
&#xd;
The nonlinear characteristics of iron core are described by the magnetizing model,&#xd;
&#xd;
the accuracy of magnetizing model is of vital importance in the analysis of DC bias.&#xd;
&#xd;
Jiles-Atherton model is derived from physical process of magnetization. With only&#xd;
&#xd;
five parameters, this model has an accurate description of magnetizing process, and&#xd;
&#xd;
easy to implement. Therefore, Jiles-Atherton model is widely accepted and used in&#xd;
&#xd;
the modeling of magnetization. However, with the development of Jiles-Atherton&#xd;
&#xd;
model, there are several editions of mathematical description, some of them are even&#xd;
&#xd;
contradict. The different expressions can easily lead to confusion and inaccuracy of&#xd;
&#xd;
modeling. This work compared several editions of Jiles-Atherton model, clarified the&#xd;
&#xd;
mathematical expression of the model based on physical properties. A modified&#xd;
&#xd;
energy conservation equation was proposed and modified Jiles-Atherton model was&#xd;
&#xd;
thus established. Numerical simulation of modified Jiles-Atherton model was carried&#xd;
&#xd;
out, the variation of B-H characteristics under different levels of DC bias were&#xd;
&#xd;
analyzed. The transformer behaviour under DC bias was analyzed with UMEC model, the&#xd;
&#xd;
result show that the magnetizing current is seriously distorted due to saturation, the&#xd;
&#xd;
harmonic components increase dramatically. The reactive power demands also&#xd;
&#xd;
increase with DC bias. Influencing factors of DC bias are also discussed. The&#xd;
&#xd;
withstanding ability of transformer to DC bias mainly depends on temperature rise&#xd;
&#xd;
and output voltage harmonics under DC bias, the influence of DC bias on&#xd;
&#xd;
temperature rise and power quality were analyzed based on filed data and limit of&#xd;
&#xd;
DC bias was given according to relevant standard.&#xd;
&#xd;
Finally, possible restraining methods to DC bias were analyzed. DC bias can be&#xd;
&#xd;
restrained by injecting reverse direct current, inserting in series with the neutral point&#xd;
&#xd;
a resistance and install capacitors and bypass device to the neutral point of main&#xd;
&#xd;
transformer.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>