<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T04:24:17Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/64962" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/64962</identifier><datestamp>2025-05-14T20:05:18Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Manickam Karthikeyan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Abhisek Ukil</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2015-06-10T01:23:27Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2015-06-10T01:23:27Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2014</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2014</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/64962</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Today's electric grid is mostly based on alternating current (AC), as well as the&#xd;
&#xd;
loads. The advance of voltage source converter-based high-voltage direct current&#xd;
&#xd;
(HVDC) transmission systems makes it possible to build a multi-terminal HVDC&#xd;
&#xd;
grid. Compared with the HVAC grids, active power conduction losses are&#xd;
&#xd;
relatively low, and reactive power conduction losses are zero in an HVDC grid.&#xd;
&#xd;
For these reasons, there is significant consideration for DC grid, but lots of open&#xd;
&#xd;
points remain to be answered. One of the most important and pivotal topics for&#xd;
&#xd;
such DC grid, is the protection, for safeguarding the grid against faults. As there is&#xd;
&#xd;
no active DC transmission grid currently (mostly there is point-to-point&#xd;
&#xd;
connection), future protection systems would be needed to be researched and&#xd;
&#xd;
developed. A thorough analysis of the technical requirements is a key point. This&#xd;
&#xd;
MSc thesis is aimed for detailed investigation about the requirements of the&#xd;
&#xd;
protection of future HVDC (HV: 69-765 kV range) grids for the transmission side.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (Power Engineering)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">61 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Requirement analysis of protection of future HVDC grid: transmission side</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="57e780c0-e8da-41ef-ae2b-fa285f535d10">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Requirement analysis of protection of future HVDC grid: transmission side&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2014&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Manickam Karthikeyan&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering&lt;/Keyword>
   	&lt;Abstract>Today&amp;apos;s electric grid is mostly based on alternating current (AC), as well as the&#xd;
&#xd;
loads. The advance of voltage source converter-based high-voltage direct current&#xd;
&#xd;
(HVDC) transmission systems makes it possible to build a multi-terminal HVDC&#xd;
&#xd;
grid. Compared with the HVAC grids, active power conduction losses are&#xd;
&#xd;
relatively low, and reactive power conduction losses are zero in an HVDC grid.&#xd;
&#xd;
For these reasons, there is significant consideration for DC grid, but lots of open&#xd;
&#xd;
points remain to be answered. One of the most important and pivotal topics for&#xd;
&#xd;
such DC grid, is the protection, for safeguarding the grid against faults. As there is&#xd;
&#xd;
no active DC transmission grid currently (mostly there is point-to-point&#xd;
&#xd;
connection), future protection systems would be needed to be researched and&#xd;
&#xd;
developed. A thorough analysis of the technical requirements is a key point. This&#xd;
&#xd;
MSc thesis is aimed for detailed investigation about the requirements of the&#xd;
&#xd;
protection of future HVDC (HV: 69-765 kV range) grids for the transmission side.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>