<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T20:50:35Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/65116" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/65116</identifier><datestamp>2025-05-01T01:43:53Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Hu, Bo</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">See Kye Yak</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="fd1602b1-1a0d-46db-93fa-8a833a7505d9" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2015-06-15T02:54:02Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2015-06-15T02:54:02Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2014</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2014</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation">Hu, B. (2014). A method for the assessment of EMI suppression performance of ferrite core loaded power cord. Doctoral thesis, Nanyang Technological University, Singapore.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10356/65116</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Clamp-on type ferrite cores are commonly employed to suppress common-mode&#xd;
&#xd;
(CM) noise currents on the attached cables without affecting the intended differential mode&#xd;
&#xd;
(OM) signal. Ferrite core manufacturers usually provide the insertion loss&#xd;
&#xd;
information of the ferrite core under pre-defined source and load conditions. Similarly,&#xd;
&#xd;
most research work has been focused on the impedance characteristics of a ferrite core&#xd;
&#xd;
and its loading effects on various types of the transmission lines. However, most of these&#xd;
&#xd;
measurement setups are still designed based on 50 0 test system. Unfortunately, the&#xd;
&#xd;
source and load impedances of the ferrite core loaded cable under the actual operating&#xd;
&#xd;
condition are usually unknown. As the insertion loss of a ferrite core depends very much&#xd;
&#xd;
on the actual source and load impedances, the predefined impedance measurement&#xd;
&#xd;
system does not reflect the true EMI suppression characteristic of a ferrite core under its&#xd;
&#xd;
actual operating configuration.&#xd;
&#xd;
An evaluation methodology of EMI suppression performance of a ferrite core&#xd;
&#xd;
loaded cable under its actual operating condition is proposed in this thesis. Based on a&#xd;
&#xd;
two-probe inductive coupling approach, the current probes are clamped on to the cable&#xd;
&#xd;
and the EMI attenuation of a ferrite core loaded power cord can be assessed more&#xd;
&#xd;
objectively without the actual operation interrupted. Taking into account the impedance&#xd;
&#xd;
of the ferrite core and the CM impedances of the intended noise source and noise&#xd;
&#xd;
termination, the true EMI suppression performance of the ferrite core located at different&#xd;
&#xd;
positions along the cable can be evaluated with confidence. Using a practical test case with an interfacing cable connecting between a mouse&#xd;
&#xd;
and a personal computer (PC), the proposed model has been validated experimentally&#xd;
&#xd;
with the measured CM noise current along the cable. The calculated insertion loss of the&#xd;
&#xd;
ferrite core based on the proposed model agrees well with the insertion loss obtained&#xd;
&#xd;
through measured CM current. Finally, using a typical power cord with a metal ground&#xd;
&#xd;
plane as the CM current return path, the EMI suppression performance of a ferrite core&#xd;
&#xd;
loaded cable is analyzed with a transmission line model terminated with the actual noise&#xd;
&#xd;
source and load. Such a model allows in-depth analysis of the influence of the length of&#xd;
&#xd;
the power cord, noise source impedance and noise termination impedance on the EMI&#xd;
&#xd;
suppression performance of a ferrite core loaded cable.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Doctor of Philosophy (EEE)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">136 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">A method for the assessment of EMI suppression performance of ferrite core loaded power cord</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="c1be89b3-ff44-4f19-8ba5-933bf8adf15e">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>A method for the assessment of EMI suppression performance of ferrite core loaded power cord&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2014&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Hu, Bo&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering&lt;/Keyword>
   	&lt;Abstract>Clamp-on type ferrite cores are commonly employed to suppress common-mode&#xd;
&#xd;
(CM) noise currents on the attached cables without affecting the intended differential mode&#xd;
&#xd;
(OM) signal. Ferrite core manufacturers usually provide the insertion loss&#xd;
&#xd;
information of the ferrite core under pre-defined source and load conditions. Similarly,&#xd;
&#xd;
most research work has been focused on the impedance characteristics of a ferrite core&#xd;
&#xd;
and its loading effects on various types of the transmission lines. However, most of these&#xd;
&#xd;
measurement setups are still designed based on 50 0 test system. Unfortunately, the&#xd;
&#xd;
source and load impedances of the ferrite core loaded cable under the actual operating&#xd;
&#xd;
condition are usually unknown. As the insertion loss of a ferrite core depends very much&#xd;
&#xd;
on the actual source and load impedances, the predefined impedance measurement&#xd;
&#xd;
system does not reflect the true EMI suppression characteristic of a ferrite core under its&#xd;
&#xd;
actual operating configuration.&#xd;
&#xd;
An evaluation methodology of EMI suppression performance of a ferrite core&#xd;
&#xd;
loaded cable under its actual operating condition is proposed in this thesis. Based on a&#xd;
&#xd;
two-probe inductive coupling approach, the current probes are clamped on to the cable&#xd;
&#xd;
and the EMI attenuation of a ferrite core loaded power cord can be assessed more&#xd;
&#xd;
objectively without the actual operation interrupted. Taking into account the impedance&#xd;
&#xd;
of the ferrite core and the CM impedances of the intended noise source and noise&#xd;
&#xd;
termination, the true EMI suppression performance of the ferrite core located at different&#xd;
&#xd;
positions along the cable can be evaluated with confidence. Using a practical test case with an interfacing cable connecting between a mouse&#xd;
&#xd;
and a personal computer (PC), the proposed model has been validated experimentally&#xd;
&#xd;
with the measured CM noise current along the cable. The calculated insertion loss of the&#xd;
&#xd;
ferrite core based on the proposed model agrees well with the insertion loss obtained&#xd;
&#xd;
through measured CM current. Finally, using a typical power cord with a metal ground&#xd;
&#xd;
plane as the CM current return path, the EMI suppression performance of a ferrite core&#xd;
&#xd;
loaded cable is analyzed with a transmission line model terminated with the actual noise&#xd;
&#xd;
source and load. Such a model allows in-depth analysis of the influence of the length of&#xd;
&#xd;
the power cord, noise source impedance and noise termination impedance on the EMI&#xd;
&#xd;
suppression performance of a ferrite core loaded cable.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>