<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-27T11:13:35Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/66035" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/66035</identifier><datestamp>2026-11-25T21:45:06Z</datestamp><setSpec>com_10356_1420</setSpec><setSpec>com_10356_21</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2324</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en">Wei, Yanyan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en">Toh Chee Seng</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en">Li Tianhu</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en" authority="07ed7c33-4ecb-4d69-9eda-16cd1f130014" confidence="600">School of Physical and Mathematical Sciences</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned" lang="en">2016-03-03T04:46:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available" lang="en">2016-03-03T04:46:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en">2016</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation" lang="en">Wei, Y. (2016). Fuel cell sensor and biosensor based on Prussian blue nanotube membrane. Doctoral thesis, Nanyang Technological University, Singapore.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/66035</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi" lang="en">10.32657/10356/66035</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">In this thesis, we presented a system of fuel cell sensor and biosensor with simple two-compartment design based on a Prussian blue nanotubes membrane. Firstly, we proposed a unique Prussian blue nanotubes sensor using a two-compartment cell derives the current signal from the chemical energy of the hydrogen peroxide analyte, without input of electrical potentials. This strategy can be further demonstrated in a model glucose biosensor when coupling with glucose oxidase. This H2O2 powered sensor was extended to fabricate a virus sensor based on the formation of antibody-virus complexes within the sensor’s membrane nanochannels for direct detection of unlabelled virus particles. This fuel cell virus sensor offered an impressive short response time of ~5 min toward the specific virus target, at low concentration values of 3 to 45 pfu mL-1. As low as 0.04 pfu mL-1 of detection limit was achieved, which was comparable to state-of-the-art PCR based methods. To simplify the sensing design, we fabricated an integrated PB-nt membrane filled with Nafion®perfluorinated resin as a standalone fuel cell based virus sensor, which offered promising potential to develop a sustainable, low cost and rapid low power virus detection tool.  Inspired from the integrate membrane probe, we demonstrated a hand-held H2O2 fuel cell sensor based on Prussian blue nanotubes membrane.  This H2O2 fuel cell sensor was constructed using four standalone nafion-filled PB-nt membranes connected in parallel, which employed the PB-nt membrane as both electrodes and fuel reservoir. An open-circuit potential (OCP) of 0.54 V with a maximum power density of 0.7 mW cm-2 has been achieved at a low concentration of 10 mM H2O2. The analytical performance of the fuel cell sensor was monitored using a micro-current meter to record the responding signal towards varying H2O2 concentrations. An excellent linear relationship has been established between the responding current signal and low concentrations of H2O2.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en">DOCTOR OF PHILOSOPHY (SPMS)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en">128 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">DRNTU::Science::Chemistry::Physical chemistry::Electrochemistry</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Fuel cell sensor and biosensor based on Prussian blue nanotube membrane</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-25T21:45:04Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="wos">2025-08-11T23:27:02Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="9ca0f9af-2dbb-45a9-a659-193654f7423f">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Fuel cell sensor and biosensor based on Prussian blue nanotube membrane&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2016&lt;/PublicationDate>
   	&lt;DOI>10.32657/10356/66035&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Wei, Yanyan&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Science::Chemistry::Physical chemistry::Electrochemistry&lt;/Keyword>
   	&lt;Abstract>In this thesis, we presented a system of fuel cell sensor and biosensor with simple two-compartment design based on a Prussian blue nanotubes membrane. Firstly, we proposed a unique Prussian blue nanotubes sensor using a two-compartment cell derives the current signal from the chemical energy of the hydrogen peroxide analyte, without input of electrical potentials. This strategy can be further demonstrated in a model glucose biosensor when coupling with glucose oxidase. This H2O2 powered sensor was extended to fabricate a virus sensor based on the formation of antibody-virus complexes within the sensor’s membrane nanochannels for direct detection of unlabelled virus particles. This fuel cell virus sensor offered an impressive short response time of ~5 min toward the specific virus target, at low concentration values of 3 to 45 pfu mL-1. As low as 0.04 pfu mL-1 of detection limit was achieved, which was comparable to state-of-the-art PCR based methods. To simplify the sensing design, we fabricated an integrated PB-nt membrane filled with Nafion®perfluorinated resin as a standalone fuel cell based virus sensor, which offered promising potential to develop a sustainable, low cost and rapid low power virus detection tool.  Inspired from the integrate membrane probe, we demonstrated a hand-held H2O2 fuel cell sensor based on Prussian blue nanotubes membrane.  This H2O2 fuel cell sensor was constructed using four standalone nafion-filled PB-nt membranes connected in parallel, which employed the PB-nt membrane as both electrodes and fuel reservoir. An open-circuit potential (OCP) of 0.54 V with a maximum power density of 0.7 mW cm-2 has been achieved at a low concentration of 10 mM H2O2. The analytical performance of the fuel cell sensor was monitored using a micro-current meter to record the responding signal towards varying H2O2 concentrations. An excellent linear relationship has been established between the responding current signal and low concentrations of H2O2.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>