<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T14:59:23Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/70619" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/70619</identifier><datestamp>2026-11-26T20:38:35Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Xiang, Shuguang</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Chan Chok You, John</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2017-05-05T06:24:46Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2017-05-05T06:24:46Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2017</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation">Xiang, S. (2017). A modified hysteresis-based DTC strategy for synchronous reluctance machines in high speed range. Master&amp;apos;s thesis, Nanyang Technological University, Singapore.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/70619</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi">10.32657/10356/70619</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Recently, synchronous reluctance machines (SynRMs) have gained popularity in certain variablespeed&#xd;
applications. In terms of torque and efficiency these machines demonstrate similar properties to&#xd;
induction machines. However, they have lower rotor losses than induction machines. Because of its&#xd;
ability to regulate flux levels, &amp;quot;spinning&amp;quot; core losses can be eliminated. This makes them preferable to&#xd;
permanent-magnet machines in scenarios where machines rotate without load torque. Furthermore,&#xd;
they are able to be applied to extremely high speeds. A flywheel energy storage system is a typical&#xd;
application which utilizes above-mentioned advantages.&#xd;
During high speed range, torque capability is of major concern. For classical hysteresis-based DTC,&#xd;
torque capability is reduced due to the fact that stator flux is weakened. In other words, the constant&#xd;
torque range is limited. In this thesis, a modified hysteresis-based direct torque control is proposed to&#xd;
extend the constant torque region. Consequently, torque capability is enhanced in high speed range&#xd;
and hence speed response time is lessened. The proposed method is based on the classical hysteresisbased&#xd;
DTC structure. Like the classical hysteresis-based DTC, the proposed method is implemented&#xd;
based on the measured currents and machine parameters.&#xd;
The modified hysteresis-based DTC is established by combining the classical hysteresis-based DTC&#xd;
with a flux error status modifying block. The block features a simple structure and an easily-executed&#xd;
algorithm, which renders it possible to fulfill even in a logic circuit. The fl~x error status block adjusts&#xd;
the flux error status produced by the flux hysteresis controller. After this, the new flux error status is&#xd;
fed into the switching table to produce the optimum voltage vector. It is worth mentioning that the&#xd;
modified flux error status is determined by flux position in the stationary reference frame a-~, which&#xd;
is fixed in space. Also, the moment to activate this block is a major factor to consider. Since the&#xd;
objective of this incorporated block is to increase torque capability in dynamic conditions, this flux&#xd;
error status modifying block should be deactivated under steady states. In this thesis, the torque error&#xd;
is analyzed continuously to decide whether the incorporated block should be triggered or not. A simulation is carried out by SIMULINK/MATLAB to confirm the suggested theory. A further&#xd;
comparison is made between the classical and the proposed hysteresis-based DTC methods. However,&#xd;
the modified DTC has relatively large torque ripples. Therefore, the torque hysteresis controller is&#xd;
replaced with a PI controller to address intrinsic disadvantages of hysteresis-based DTC.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Engineering</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">81 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">A modified hysteresis-based DTC strategy for synchronous reluctance machines in high speed range</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-26T20:38:34Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="wos">2025-08-14T00:33:30Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="5e57339c-922d-4dd4-bb24-6ab8a85247f4">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>A modified hysteresis-based DTC strategy for synchronous reluctance machines in high speed range&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2017&lt;/PublicationDate>
   	&lt;DOI>10.32657/10356/70619&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Xiang, Shuguang&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering&lt;/Keyword>
   	&lt;Abstract>Recently, synchronous reluctance machines (SynRMs) have gained popularity in certain variablespeed&#xd;
applications. In terms of torque and efficiency these machines demonstrate similar properties to&#xd;
induction machines. However, they have lower rotor losses than induction machines. Because of its&#xd;
ability to regulate flux levels, &amp;quot;spinning&amp;quot; core losses can be eliminated. This makes them preferable to&#xd;
permanent-magnet machines in scenarios where machines rotate without load torque. Furthermore,&#xd;
they are able to be applied to extremely high speeds. A flywheel energy storage system is a typical&#xd;
application which utilizes above-mentioned advantages.&#xd;
During high speed range, torque capability is of major concern. For classical hysteresis-based DTC,&#xd;
torque capability is reduced due to the fact that stator flux is weakened. In other words, the constant&#xd;
torque range is limited. In this thesis, a modified hysteresis-based direct torque control is proposed to&#xd;
extend the constant torque region. Consequently, torque capability is enhanced in high speed range&#xd;
and hence speed response time is lessened. The proposed method is based on the classical hysteresisbased&#xd;
DTC structure. Like the classical hysteresis-based DTC, the proposed method is implemented&#xd;
based on the measured currents and machine parameters.&#xd;
The modified hysteresis-based DTC is established by combining the classical hysteresis-based DTC&#xd;
with a flux error status modifying block. The block features a simple structure and an easily-executed&#xd;
algorithm, which renders it possible to fulfill even in a logic circuit. The fl~x error status block adjusts&#xd;
the flux error status produced by the flux hysteresis controller. After this, the new flux error status is&#xd;
fed into the switching table to produce the optimum voltage vector. It is worth mentioning that the&#xd;
modified flux error status is determined by flux position in the stationary reference frame a-~, which&#xd;
is fixed in space. Also, the moment to activate this block is a major factor to consider. Since the&#xd;
objective of this incorporated block is to increase torque capability in dynamic conditions, this flux&#xd;
error status modifying block should be deactivated under steady states. In this thesis, the torque error&#xd;
is analyzed continuously to decide whether the incorporated block should be triggered or not. A simulation is carried out by SIMULINK/MATLAB to confirm the suggested theory. A further&#xd;
comparison is made between the classical and the proposed hysteresis-based DTC methods. However,&#xd;
the modified DTC has relatively large torque ripples. Therefore, the torque hysteresis controller is&#xd;
replaced with a PI controller to address intrinsic disadvantages of hysteresis-based DTC.&lt;/Abstract>