<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T04:44:20Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/73791" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/73791</identifier><datestamp>2026-11-24T21:40:46Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Kulathunga S.M. Asiri Indrajith</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Cai Wenjian</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2018-04-11T08:41:29Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2018-04-11T08:41:29Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2018</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation">Kulathunga S.M. Asiri Indrajith. (2018). Modeling and optimization of vacuumed regeneration process for liquid desiccant dehumidification system. Doctoral thesis, Nanyang Technological University, Singapore.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/73791</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi">10.32657/10356/73791</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Since the last few decades the world has been facing global warming due to the&#xd;
increased percentage of atmospheric CO2. Much attention is therefore devoted to building&#xd;
air conditioning and, mechanical ventilation (ACMV) systems to provide a comfortable&#xd;
environment to occupants of residential houses and buildings. Liquid Desiccant&#xd;
Dehumidification System (LDDS) has gained much attention due to the possibility of&#xd;
combining secondary level energy sources like renewable energy and waste heat as its main&#xd;
energy source. However, the regeneration process of LDDS absorbs a vast amount of heat&#xd;
to vaporize water from the weak desiccant solution. With proper study and investigation&#xd;
nevertheless, challenges such as the requirement of high temperature heat sources,&#xd;
inefficiency of the regeneration process, and the complexity of combining renewable&#xd;
energy sources with the regeneration system can be overcome.&#xd;
&#xd;
Thus, a new vacuumed regenerator was designed to improve key performance&#xd;
indices of the regeneration process, while taking important parameters into consideration,&#xd;
such as; evaporator and condenser heat, mass transfer mechanism and driving force,&#xd;
solution flow method through the heat exchanger, condenser tube arrangement and liquid&#xd;
desiccant properties. Vacuumed condition of the regenerator increases the mass transfer&#xd;
driving force and reduces the evaporation temperature of the water; thus lowering the&#xd;
required heat source temperature. Carry over effect of the liquid desiccant is prevented, by&#xd;
making the regenerator a fully closed system where liquid desiccant circulates internally,&#xd;
with no direct contact with other fluids.&#xd;
&#xd;
Data was collected by testing the system to study the regeneration performance,&#xd;
with respect to different parameter conditions like; hot water and chilled water temperatures&#xd;
and flow rates, solution flow rate, initial solution concentration and initial vacuum pressure.&#xd;
Mathematical models for the water vapour evaporation, and water vapour condensation&#xd;
processes of the regeneration system, were developed. Overall heat and mass transfer&#xd;
coefficients for evaporator were modeled, by considering external convection over a tube&#xd;
bank and internal convection of a cylindrical tube. Evaporator mass transfer Sherwood&#xd;
number was modeled as a function of two phases Reynolds number, Schmidt number,&#xd;
concentration gradient and heat flux. Both evaporator heat transfer and mass transfer&#xd;
models were validated within ±10% good agreement with actual results. Condensation&#xd;
process was modeled by considering external natural condensation over a tube bank and&#xd;
internal convection of a cylindrical tube. Heat transfer rate of the condensation process is a&#xd;
function of chilled water flow rate, mean temperature difference and the number of rows of&#xd;
tubes. The heat transfer and mass transfer models for the condensation process were&#xd;
validated within ±10% good agreement with actual values. This theoretical contribution can&#xd;
be equally applied to any kind of similar system by changing system dependent parameters.&#xd;
&#xd;
Finally, optimization for the developed model was conducted to identify the best&#xd;
operating condition of the system. Minimizing total energy consumption and maximizing&#xd;
heat and mass transfer of evaporation and condensation processes were set as objectives of&#xd;
the multi objective genetic algorithm optimization. MATLAB’s genetic algorithm tool was&#xd;
employed for the optimization calculation, and it was found that the optimum condition can&#xd;
be achieved by several combinations of constraint parameters. Hence, a suitable solution&#xd;
was selected from the optimum settings by considering the resource availability and&#xd;
economic factors. It was found that the optimum output can be achieved from a low&#xd;
temperature heat source around 38 0C, chilled water temperature of 8 0C with a vacuum&#xd;
condition of 695 Pa.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Doctor of Philosophy (EEE)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">248 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Modeling and optimization of vacuumed regeneration process for liquid desiccant dehumidification system</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-24T21:40:44Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="wos">2025-08-14T00:59:43Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="5b253b07-f61f-42ae-b9a5-90f358c17ae4">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Modeling and optimization of vacuumed regeneration process for liquid desiccant dehumidification system&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2018&lt;/PublicationDate>
   	&lt;DOI>10.32657/10356/73791&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Kulathunga S.M. Asiri Indrajith&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering&lt;/Keyword>
   	&lt;Abstract>Since the last few decades the world has been facing global warming due to the&#xd;
increased percentage of atmospheric CO2. Much attention is therefore devoted to building&#xd;
air conditioning and, mechanical ventilation (ACMV) systems to provide a comfortable&#xd;
environment to occupants of residential houses and buildings. Liquid Desiccant&#xd;
Dehumidification System (LDDS) has gained much attention due to the possibility of&#xd;
combining secondary level energy sources like renewable energy and waste heat as its main&#xd;
energy source. However, the regeneration process of LDDS absorbs a vast amount of heat&#xd;
to vaporize water from the weak desiccant solution. With proper study and investigation&#xd;
nevertheless, challenges such as the requirement of high temperature heat sources,&#xd;
inefficiency of the regeneration process, and the complexity of combining renewable&#xd;
energy sources with the regeneration system can be overcome.&#xd;
&#xd;
Thus, a new vacuumed regenerator was designed to improve key performance&#xd;
indices of the regeneration process, while taking important parameters into consideration,&#xd;
such as; evaporator and condenser heat, mass transfer mechanism and driving force,&#xd;
solution flow method through the heat exchanger, condenser tube arrangement and liquid&#xd;
desiccant properties. Vacuumed condition of the regenerator increases the mass transfer&#xd;
driving force and reduces the evaporation temperature of the water; thus lowering the&#xd;
required heat source temperature. Carry over effect of the liquid desiccant is prevented, by&#xd;
making the regenerator a fully closed system where liquid desiccant circulates internally,&#xd;
with no direct contact with other fluids.&#xd;
&#xd;
Data was collected by testing the system to study the regeneration performance,&#xd;
with respect to different parameter conditions like; hot water and chilled water temperatures&#xd;
and flow rates, solution flow rate, initial solution concentration and initial vacuum pressure.&#xd;
Mathematical models for the water vapour evaporation, and water vapour condensation&#xd;
processes of the regeneration system, were developed. Overall heat and mass transfer&#xd;
coefficients for evaporator were modeled, by considering external convection over a tube&#xd;
bank and internal convection of a cylindrical tube. Evaporator mass transfer Sherwood&#xd;
number was modeled as a function of two phases Reynolds number, Schmidt number,&#xd;
concentration gradient and heat flux. Both evaporator heat transfer and mass transfer&#xd;
models were validated within ±10% good agreement with actual results. Condensation&#xd;
process was modeled by considering external natural condensation over a tube bank and&#xd;
internal convection of a cylindrical tube. Heat transfer rate of the condensation process is a&#xd;
function of chilled water flow rate, mean temperature difference and the number of rows of&#xd;
tubes. The heat transfer and mass transfer models for the condensation process were&#xd;
validated within ±10% good agreement with actual values. This theoretical contribution can&#xd;
be equally applied to any kind of similar system by changing system dependent parameters.&#xd;
&#xd;
Finally, optimization for the developed model was conducted to identify the best&#xd;
operating condition of the system. Minimizing total energy consumption and maximizing&#xd;
heat and mass transfer of evaporation and condensation processes were set as objectives of&#xd;
the multi objective genetic algorithm optimization. MATLAB’s genetic algorithm tool was&#xd;
employed for the optimization calculation, and it was found that the optimum condition can&#xd;
be achieved by several combinations of constraint parameters. Hence, a suitable solution&#xd;
was selected from the optimum settings by considering the resource availability and&#xd;
economic factors. It was found that the optimum output can be achieved from a low&#xd;
temperature heat source around 38 0C, chilled water temperature of 8 0C with a vacuum&#xd;
condition of 695 Pa.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>