<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T03:04:52Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/76330" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/76330</identifier><datestamp>2025-05-14T17:03:35Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Kawin, Asavathiratham</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Cai Wenjian</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2018-12-19T14:21:06Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2018-12-19T14:21:06Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2018</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/76330</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">An HVAC system is responsible for the ambient control of air temperature and&#xd;
ventilation. It consists of a multiple sub-system. One of them is the air handing unit or&#xd;
AHU, it’s responsible for the air ventilation of a building. It’s a single fan or a fan array&#xd;
in the AHU. It is an important element to force air along the system. In this component&#xd;
most of the systems consist of a single fan but nowadays the use of fan arrays are&#xd;
increasing. Even though the fan array consumes more power and energy than a large&#xd;
single fan, it offers better continuity and distribution of air flow along the system.&#xd;
According to the U.S. Energy Information Administration report on commercial&#xd;
buildings, 16 percent of the electricity is consumed in the ventilation process. Therefore,&#xd;
optimizing the fan array is significant for energy saving.&#xd;
The study uses a fan model created from the manufacturer with the specifications of the&#xd;
fan’s performance graph curve using the aerodynamics and physics of the fan’s velocity&#xd;
laws. However, the model has fan speed limitations. Every fan in the fan array must&#xd;
rotate at the same speed. Therefore, the simulation can show approximately optimal&#xd;
operating point.&#xd;
Although the study wasn’t done within an air handling unit (AHU). The control design is&#xd;
shown and explained in the last part of this report. The fan array controller is ARM&#xd;
STM32 with a support board. This report describes the initial design of the controller&#xd;
preparing the implementation to a fan array in air handling unit.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (Computer Control and Automation)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">65 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Optimization of fan array in air handling unit</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="29a59326-1456-4b21-a8d9-3388dff97b0b">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Optimization of fan array in air handling unit&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2018&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Kawin, Asavathiratham&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering&lt;/Keyword>
   	&lt;Abstract>An HVAC system is responsible for the ambient control of air temperature and&#xd;
ventilation. It consists of a multiple sub-system. One of them is the air handing unit or&#xd;
AHU, it’s responsible for the air ventilation of a building. It’s a single fan or a fan array&#xd;
in the AHU. It is an important element to force air along the system. In this component&#xd;
most of the systems consist of a single fan but nowadays the use of fan arrays are&#xd;
increasing. Even though the fan array consumes more power and energy than a large&#xd;
single fan, it offers better continuity and distribution of air flow along the system.&#xd;
According to the U.S. Energy Information Administration report on commercial&#xd;
buildings, 16 percent of the electricity is consumed in the ventilation process. Therefore,&#xd;
optimizing the fan array is significant for energy saving.&#xd;
The study uses a fan model created from the manufacturer with the specifications of the&#xd;
fan’s performance graph curve using the aerodynamics and physics of the fan’s velocity&#xd;
laws. However, the model has fan speed limitations. Every fan in the fan array must&#xd;
rotate at the same speed. Therefore, the simulation can show approximately optimal&#xd;
operating point.&#xd;
Although the study wasn’t done within an air handling unit (AHU). The control design is&#xd;
shown and explained in the last part of this report. The fan array controller is ARM&#xd;
STM32 with a support board. This report describes the initial design of the controller&#xd;
preparing the implementation to a fan array in air handling unit.&lt;/Abstract>