<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T14:27:31Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/89435" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/89435</identifier><datestamp>2026-11-23T20:30:06Z</datestamp><setSpec>com_10356_982</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2152</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en">Chen, Kang</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en">Tan Kang Hai</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en" authority="a6dec9ca-977d-49d3-af9e-2924bad6cbb7" confidence="600">School of Civil and Environmental Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="research" lang="en" authority="c597c226-ac7f-4438-8c23-d5dcbc1de9fc" confidence="600">Protective Technology Research Centre</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned" lang="en">2018-10-11T05:34:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2019-12-06T17:25:26Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available" lang="en">2018-10-11T05:34:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2019-12-06T17:25:26Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en">2018</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation" lang="en">Chen, K. (2018). Behaviour of steel and composite beam-column joints under extreme loading conditions. Doctoral thesis, Nanyang Technological University, Singapore.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/89435</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi" lang="en">10.32657/10220/46284</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Historical collapse incidents of buildings under extreme loadings have attracted&#xd;
academic and engineering interest to conduct research studies on the resistance of&#xd;
beam-column joints to mobilise alternate load path and develop catenary action, in&#xd;
order to bridge over lost structural members. The integrity of beam-column joints&#xd;
greatly influences the capability of structures to develop catenary action. Up to date,&#xd;
experimental tests have been conducted for various types of beam-column joints&#xd;
subjected to column removal scenarios, which are widely used as a threatindependent&#xd;
approach to represent structural damages caused by extreme loadings.&#xd;
However, experimental programmes on composite joints with fin plate (also referred&#xd;
to as shear tab) and welded unreinforced flange bolted web connections are very&#xd;
limited, although these two types of joints are quite common in industrial practice.&#xd;
In the current study, experimental tests on steel and composite beam-column joints&#xd;
were conducted. Two types of connections, viz. fin plate and welded unreinforced&#xd;
flange bolted web connections were investigated under both quasi-static and impact&#xd;
loading scenarios. The load-resisting mechanism, failure mode, energy absorption&#xd;
and development of strain were presented based on test results. Tying and flexural&#xd;
resistances, as well as rotation capacities, were compared with design values. A&#xd;
comparison of quasi-static and impact tests was also conducted to quantify the&#xd;
contribution of strain rate effect. Furthermore, two connections, viz. fin plate&#xd;
connection with slotted holes and reduced beam section connection were conducted&#xd;
for comparison purposes. It was found that they contributed to better tying resistance&#xd;
and rotation capacity in comparison with conventional connections. In addition,&#xd;
numerical analyses on steel beam-column joints under impact loading scenarios were&#xd;
conducted. Three-dimensional finite element models in commercial software LSDYNA&#xd;
were established and validated by test results with reasonably good accuracy.&#xd;
The models were used to compare two proposed evaluation indices by the author,&#xd;
namely, energy absorption ratio and deformation ratio for steel joints subjected to&#xd;
impact loads.&#xd;
Based on test results, a component-based modelling approach for beam-column&#xd;
joints with fin plate and welded unreinforced flange bolted web connections was proposed. The arrangement of nonlinear springs representing steel components was&#xd;
adopted from Eurocode and was combined with composite slab components.&#xd;
Furthermore, nonlinear spring properties were defined on the basis of component test&#xd;
results and design codes. The proposed models were able to simulate the behaviour&#xd;
of beam-column joints subjected to quasi-static and impact loads with adequate&#xd;
accuracy. Composite slab effect and strain rate were also considered by the proposed&#xd;
modelling approach.&#xd;
In general, the current design calculation method was found to overestimate the tying&#xd;
resistance of both types of composite joints, especially when thicker slabs or fewer&#xd;
shear studs were used. The overestimation is less evident for WUF-B joints&#xd;
compared to FP joints. The novel FP joint was able to develop the design values of&#xd;
tying resistance in the test. The design values of flexural resistance and rotation&#xd;
capacity could be achieved by the test, especially when the beneficial effect of&#xd;
intermediate strain-rate was included. The aforementioned issues of the design&#xd;
method could be solved by using the proposed modelling approach, which could be&#xd;
used in design practice for engineers.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en">Doctor of Philosophy</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en">254 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">DRNTU::Engineering::Civil engineering::Structures and design</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Behaviour of steel and composite beam-column joints under extreme loading conditions</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-23T20:30:04Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="wos">2025-08-14T00:01:06Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>
   <dim:field mdschema="datacite" element="available">2018-10-15</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="8c3e80cd-8966-4142-aa44-eb4f5a648030">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Behaviour of steel and composite beam-column joints under extreme loading conditions&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2018&lt;/PublicationDate>
   	&lt;DOI>10.32657/10220/46284&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Chen, Kang&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Civil engineering::Structures and design&lt;/Keyword>
   	&lt;Abstract>Historical collapse incidents of buildings under extreme loadings have attracted&#xd;
academic and engineering interest to conduct research studies on the resistance of&#xd;
beam-column joints to mobilise alternate load path and develop catenary action, in&#xd;
order to bridge over lost structural members. The integrity of beam-column joints&#xd;
greatly influences the capability of structures to develop catenary action. Up to date,&#xd;
experimental tests have been conducted for various types of beam-column joints&#xd;
subjected to column removal scenarios, which are widely used as a threatindependent&#xd;
approach to represent structural damages caused by extreme loadings.&#xd;
However, experimental programmes on composite joints with fin plate (also referred&#xd;
to as shear tab) and welded unreinforced flange bolted web connections are very&#xd;
limited, although these two types of joints are quite common in industrial practice.&#xd;
In the current study, experimental tests on steel and composite beam-column joints&#xd;
were conducted. Two types of connections, viz. fin plate and welded unreinforced&#xd;
flange bolted web connections were investigated under both quasi-static and impact&#xd;
loading scenarios. The load-resisting mechanism, failure mode, energy absorption&#xd;
and development of strain were presented based on test results. Tying and flexural&#xd;
resistances, as well as rotation capacities, were compared with design values. A&#xd;
comparison of quasi-static and impact tests was also conducted to quantify the&#xd;
contribution of strain rate effect. Furthermore, two connections, viz. fin plate&#xd;
connection with slotted holes and reduced beam section connection were conducted&#xd;
for comparison purposes. It was found that they contributed to better tying resistance&#xd;
and rotation capacity in comparison with conventional connections. In addition,&#xd;
numerical analyses on steel beam-column joints under impact loading scenarios were&#xd;
conducted. Three-dimensional finite element models in commercial software LSDYNA&#xd;
were established and validated by test results with reasonably good accuracy.&#xd;
The models were used to compare two proposed evaluation indices by the author,&#xd;
namely, energy absorption ratio and deformation ratio for steel joints subjected to&#xd;
impact loads.&#xd;
Based on test results, a component-based modelling approach for beam-column&#xd;
joints with fin plate and welded unreinforced flange bolted web connections was proposed. The arrangement of nonlinear springs representing steel components was&#xd;
adopted from Eurocode and was combined with composite slab components.&#xd;
Furthermore, nonlinear spring properties were defined on the basis of component test&#xd;
results and design codes. The proposed models were able to simulate the behaviour&#xd;
of beam-column joints subjected to quasi-static and impact loads with adequate&#xd;
accuracy. Composite slab effect and strain rate were also considered by the proposed&#xd;
modelling approach.&#xd;
In general, the current design calculation method was found to overestimate the tying&#xd;
resistance of both types of composite joints, especially when thicker slabs or fewer&#xd;
shear studs were used. The overestimation is less evident for WUF-B joints&#xd;
compared to FP joints. The novel FP joint was able to develop the design values of&#xd;
tying resistance in the test. The design values of flexural resistance and rotation&#xd;
capacity could be achieved by the test, especially when the beneficial effect of&#xd;
intermediate strain-rate was included. The aforementioned issues of the design&#xd;
method could be solved by using the proposed modelling approach, which could be&#xd;
used in design practice for engineers.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>